Ventis Pro 5 & Pro Series Advanced Portable Gas Detectors

The Ventis™ Pro Series of multi-gas portable gas detectors is designed for people who would otherwise need to carry multiple units to detect multiple gasses.

Whether you need unique 4-gas or expanded 5-gas sensor options, Ventis Pro is the most configurable multi-gas detector on the market.

  • Flexible sensor configurations can detect up to 5 gases.
  • Custom start-up messages, alarm action messages, and acknowledgeable gas alerts.
  • Man-down alarm and dedicated panic button.
  • User and site tracking with iAssign™ Technology.
  • Rugged IP68 water and dust rating and Guaranteed for Life™ warranty.
  • Available with or without a pump.
  • Compatible with most Ventis MX4 accessories.
  • Dock overdue and maintenance reminders.
  • iNet® and DSX™ Docking Station ready.


      Stop carrying so many units! Ventis Pro multi-gas detector with unique 4-gas or expanded 5-gas sensors. The most configurable multi-gas detectors available.

      In your line of work, a day on the job can turn from habit to hazard in the blink of an eye. Be ready for gas hazards with the Ventis Pro series of multi-gas portable gas detectors from Industrial Scientific.

      Detect up to 5 gases: You can rely on flexible sensor options to detect combustible and toxic gases in a broad range of settings. This makes the Ventis Pro series ideal for both personal protection and confined space applications.

      Simplify gas detection for your workers: You have the ability to create custom start-up messages to communicate safety information to your team, hide screens from users for simplified use, acknowledge low gas levels, and receive written instructions when a detector goes into alarm.

      React in emergency situations: You will know when a worker is in distress or has lost consciousness thanks to a dedicated panic button and man-down alarm.

      Track detectors and alarms: Manage recurring alarms and improve asset management by assigning users and sites to each gas detector in real time using Industrial Scientific’s iAssign™ Technology.

      Dependable, rugged design: With an IP68 rating for dust and water ingress and a rugged overmould that is Guaranteed for Life, you can keep your detectors in the field, not the shop.

      Upgrade with ease: There is no need to buy all-new accessories. Most of your Ventis MX4 accessories are compatible with the Ventis Pro Series.


      Specifications

      Property Details
      Instrument Warranty Guaranteed for Life. Warranted for as long as the instrument is supported by Industrial Scientific Corporation (excludes sensors, batteries, and filters). O2, LEL, CO, and H2S sensors warranted for three years. All other sensors warranted for two years. Pumps and batteries are warranted for two years.
      Keypad Two buttons for operation. Dedicated panic button.
      Data Log At least 3 months at 10-second intervals
      Event Logging 60 alarm events
      Ingress Protection IP68 (submersion at 1.5 meters for 1 hour)
      Case Material Polycarbonate with protective rubber overmould
      Dimensions 104mm x 58mm x 36mm without pump
      172mm x 67mm x 65mm with pump
      Weight 200g, typical without pump
      390g, typical with pump
      Temperature Range -40°C to 50°C
      Humidity Range 15%-95% Non-condensing
      Display / Readout Backlit liquid crystal display (LCD)
      Power Source / Run Time Rechargeable lithium-ion battery pack with LEL:
      • 12 hours typical @ 20ºC – without pumpRechargeable extended-range lithium-ion battery pack with LEL:
      • 24 hours typical @ 20ºC – without pump
      • 18 hours typical @ 20ºC – with pump

      Rechargeable lithium-ion battery pack with IR:
      • 36 hours typical @ 20ºC – without pump

      Rechargeable extended-range lithium-ion battery pack with IR:
      • 72 hours typical @ 20ºC – without pump
      • 32 hours typical @ 20ºC – with pump

      Alarms Four visual alarm LEDs (two red, two blue)
      95 decibel (dB) audible alarm at a distance of 10cm
      Vibration alarm
      Supplied With Monitor Calibration Cup (Ventis), Sample Tubing (Ventis with pump), Reference Guide
      Sensors Combustible Gases/Methane – Catalytic Bead
      O2, CO, CO/H2 low, H2S, HCN, NH3, NO2, SO2 – Electrochemical
      CO2/HC, CO2/CH4 – Infrared
      Measuring Ranges Catalytic Bead:
      • Combustible Gases: 0-100% LEL in 1% increments
      • Methane (CH4): 0-5% of vol. in 0.01% incrementsElectrochemical:
      • Ammonia: 0-500 ppm in 1 ppm increments
      • Carbon Monoxide (CO): 0-2,000 ppm in 1 ppm increments
      • Carbon Monoxide (CO/H2 low): 0-1,000 ppm in 1 ppm increments
      • Carbon Monoxide/Hydrogen Sulfide: CO: 0-1,500 ppm in 1 ppm increments
      • H2S: 0-500 ppm in 0.1 ppm increments
      • Hydrogen Sulfide (H2S): 0-500 ppm in 0.1 ppm increments
      • Hydrogen Cyanide: 0-30 ppm in 0.1 ppm increments
      • Nitrogen Dioxide (NO2): 0-150 ppm in 0.1 ppm increments
      • Oxygen (O2): 0-30% of vol. in 0.1% increments
      • Sulfur Dioxide (SO2): 0-150 ppm in 0.1 ppm increments

      Infrared:
      • Carbon Dioxide/Hydrocarbons:
      – CO2: 0-5% vol in 0.01% increments
      – HC: 0-100% LEL in 1% increments
      • Carbon Dioxide/Methane:
      – CO2: 0-5% vol in 0.01% increments
      – CH4: 0-5% vol in 0.01% increments
      – CH4: 5-100% vol in 0.1% increments

      Certifications UL:
      • Class I, Division 1, Groups A, B, C, and D, in the Temperature Class T4
      • Class II, Division 1, Groups E, F, and G, in the Temperature Class T4
      • Class I, Zone 0, AEx ia IIC, in the Temperature Class T4
      • Class I, Zone 1, AEx d ia II C, in the Temperature Class T4, with IR sensorATEX:
      • Equipment Group and Category II 1G, Ex ia IIC, with the protection category Ga, in the Temperature Class T4
      • Equipment Group and Category II 2G, Ex d ia IIC, with the protection category Gb, in the Temperature Class T4, with IR sensor

      IECEx:
      • Class I, Zone 0, Ex ia IIC, with the protection technique Ga, in the Temperature Class T4
      • Class I, Zone 1, Ex d ia IIC, with the protection technique Gb, in the Temperature Class T4, with IR sensor

      CSA:
      • Class I, Division 1, Groups A, B, C, and D, in the Temperature Class T4
      • Class I, Zone 1, Ex d ia IIC, in the Temperature Class T4

      Common Configurations

      Part Number Description
      Ventis Pro5 logo
      VP5‑KJ532111y01 Ventis Pro5 with pump: LEL (Pent), CO/H2S, SO2, O2, Extended Li-ion, Desktop Charger, Orange
      VP5‑KJ431101y01 Ventis Pro5: LEL (Pent), CO/H2S, NO2, O2, Li-ion, Desktop Charger, Orange
      VP5‑KJ632110y01 Ventis Pro5 with pump: LEL (Pent), CO/H2S, NH3, O2, Extended Li-ion, Desktop Charger, Black
      VP5‑U1232110y01 Ventis Pro5 with pump: CO2/HC IR, CO, H2S, O2, Extended Li-ion, Desktop Charger, Black
      VP5‑U1632111y01 Ventis Pro5 with pump: CO2/HC IR, CO, NH3, O2, Extended Li-ion, Desktop Charger, Orange
      Ventis Pro4 logo
      VP4‑K1231101y01 Ventis Pro4: LEL (Pent), CO, H2S, O2, Li-ion, Desktop Charger, Orange
      VP4‑K1232110y01 Ventis Pro4 with pump: LEL (Pent), CO, H2S, O2, Extended Li-ion, Desktop Charger, Black
      VP4‑K5231101y01 Ventis Pro4: LEL (Pent), SO2, H2S, O2, Li-ion, Desktop Charger, Orange
      VP4‑K1431101y01 Ventis Pro4: LEL (Pent), CO, NO2, O2, Li-ion, Desktop Charger, Orange
      VP4‑K1B31101y01 Ventis Pro4: LEL (Pent), CO, HCN, O2, Li-ion, Desktop Charger, Orange
      VP4‑K1B32111y01 Ventis Pro4 with pump: LEL (Pent), CO, HCN, O2, Extended Li-ion, Desktop Charger, Orange
      y = Agency Certification: 1 = UL/CSA, 2 = ATEX/IECEx

       

      Industry-Specific Configurations

      Industry Description Hazard
      Oil & Gas Refining Standard 4-Gas + SO2 SO2 released when oil burns
      Oil & Gas Exploration Standard 4-Gas + CO2 CO2 used in fracking
      Fire Fighting Standard 4-Gas + HCN HCN release in burning plastics
      Power Generation Standard 4-Gas + SO2 Burning coal or oil for fuel
      Refrigeration NH3 or CO2 NH3 or CO2 are coolants
      Gas Utility CH4, IR, CO, O2 High-range CH4 detection
      Steel CO, H2S, SO2, NH3 Four toxics
      Coal Mining CH4 IR (Dual Range) One instrument for personal protection and seal checking
      Metal Mining Standard 4-Gas + HCN Cyanide used to separate gold from rock

      PDF Downloads

      pdf-icon Ventis Pro Series Manual Download PDF
      pdf-icon Ventis Pro Reference Guide Download PDF
      pdf-icon Ventis Pro Product Guide Download PDF
      pdf-icon Ventis Pro Ordering Guide Download PDF
      pdf-icon Application Notes – Advanced Alarm Capabilities Download PDF
      pdf-icon Application Notes – iAssign™ Technology Download PDF
      pdf-icon Application Notes – Sensor Flexibility Download PDF